Okidata 320/321 Turbo Printer Settings 1) Turn Printer off and back on. Drop a blank sheet of paper into printer. On the front of the printer face plate, press the Menu and Shift buttons at the same time so a Menu light appears. 2) Press the Park button. The printer will print a sheet of the current printer settings. 3) Repeat Step 1 to reset your printer. Locate the Group, Item, and Set buttons. The client PC is using the Okidata ML 320 Driver found under the advanced tab of the printer. Also, on the RDS host, i have the following ports: I have tried all the TS00x ports and still can not get it to print. Just to recap: i have the same okidata on the server that is on the client pc. Okidata - Oki 320 Turbo Printer Complete, Parallel Interface. More Buying Choices $349.99 (1 used offer) OKI Data B4600 27ppm LED Digital Monochrome Printer - White (62427201) 3.3 out of 5 stars 36. $299.99 $ 299. 99 $340.99 $ 340. FREE Shipping. Only 6 left in stock - order soon. These are the buttons you will be working with. 4) Press the Group button. Microsoft alt key codes. This is the first line that will need to be changed. It needs to say (ML). Change this by pressing the Set button. 5) Press the Group button 5 times until the line says (Top Feed). Press the Item button. This line needs to be changed to say (Invalid), press the Set Button. 6) Press the Group button again until the line says (Uni-directional). Press the Set button so the line reads (Bi-directional). 7) Press the Item button 3 times until the line says (Page out override). Press the Set button so this line reads (Yes). 8) Press the Item button 8 times until the line says (Time out Print). Press the Set button until this line reads (Invalid). 9) Press the Item button once so the line says (Auto Select). Press the Set button until the line reads (Yes). 10) Press the Item button once so the line says (Centering Position). Press the Set button until the line says (MODE1). 11) This is the last change you will need to make. Press the Menu and Shift buttons at the same time so the Menu light turns off. If you are still unable to properly set your printer, you may call our office for support. It's really nice to know that service manuals might be available for CyberPower. The two UPS's that I have were both fixed with new batteries. I hate it, that the ones I have (APC, Trip-Lite) don't work at all without a battery that works. APC's website just plain annoys me. Nearly as bad a Verizon's. The RB1290 UPS Replacement Battery Cartridge restores life to CyberPower UPS systems that have weak or completely depleted internal batteries. The RB1290 contains one 12V/9AH battery, certified to meet or exceed original manufacturer specifications. This leak-proof, sealed lead-acid battery never requires replacement fluid. Cyberpower ups repair. This will incur a phone support charge. Copyright © 1997 by Automotive Marketing Profit Systems. All Rights Reserved. Back to Main.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |